What was found
AFT WET AREA LT BEAM CORRODED BETWEEN LT AND CENTER SHEAR PANELS. REMOVED AND REPLACED AFT WET AREA LT BEAM BETWEEN LT AND CENTER SHEAR PANELS IAW SRM 51-40-08.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT WET AREA LT BEAM CORRODED BETWEEN LT AND CENTER SHEAR PANELS. REMOVED AND REPLACED AFT WET AREA LT BEAM BETWEEN LT AND CENTER SHEAR PANELS IAW SRM 51-40-08.