What was found
FLOOR EMERGENCY LIGHTS (FRONT HALF) DIM, 1 SECTION OUT NEAR EMERGENCY EXIT. REMOVED FORWARD EMERGENCY LIGHTING BATTERY PACK (ELBP) IN CABIN CEILING AND REPLACED WITH SERVICEABLE ELBP. FOUND ONE FLOOR LIGHT SECTION UNPLUGGED. REPLUGGED THAT SECTION. OPS CHECK GOOD IAW CRJ MM 33-51-01 AND 33-51-04.