What was found
ON TAKEOFF OUT OF 2500 FT, THE NR 1 GENERATOR WENT OFFLINE. FOLLOWED QRH, ATTEMPTED TO RESET IT AND THE ADG DEPLOYED. RETURNED TO LAX. REMOVED AND REPLACED NR 1 IDG, GCU AND SERVICED NR 2 IDG WITH OIL. GROUND RAN. OPS CHECKS GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON TAKEOFF OUT OF 2500 FT, THE NR 1 GENERATOR WENT OFFLINE. FOLLOWED QRH, ATTEMPTED TO RESET IT AND THE ADG DEPLOYED. RETURNED TO LAX. REMOVED AND REPLACED NR 1 IDG, GCU AND SERVICED NR 2 IDG WITH OIL. GROUND RAN. OPS CHECKS GOOD.