What was found
STALL FAIL MESSAGE INFLIGHT. RETURNED TO SLC. RESET MEMORY ON CH1 & CH2 IN STALL COMPUTER IAW MM 27-35-01. PERFORMED TEST OF STALL SYSTEM. OPS CHECK GOOD, NO FAULTS NOTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STALL FAIL MESSAGE INFLIGHT. RETURNED TO SLC. RESET MEMORY ON CH1 & CH2 IN STALL COMPUTER IAW MM 27-35-01. PERFORMED TEST OF STALL SYSTEM. OPS CHECK GOOD, NO FAULTS NOTED.