What was found
AMBER CAUTION MESSAGE FOR PITOT BASE HEAT ILLUMINATED @ 10,000. RETURNED TO SLC. REMOVED AND REPLACED #2 PITOT TUBE IAW CRJ MM 34-11-01. PERFORMED OPS CHEAK & LEAK CHECK IAW 34-11-00. OPS CHECKS GOOD. PN 667-0658 SN 201354.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AMBER CAUTION MESSAGE FOR PITOT BASE HEAT ILLUMINATED @ 10,000. RETURNED TO SLC. REMOVED AND REPLACED #2 PITOT TUBE IAW CRJ MM 34-11-01. PERFORMED OPS CHEAK & LEAK CHECK IAW 34-11-00. OPS CHECKS GOOD. PN 667-0658 SN 201354.