What was found
FS 280.00 RBL 9.0 FLOOR BEAM INBOARD AND OUTBOARD ANGLES FOUND CRACKED DURING C-CHECK INSPECTION. FIT AND INSTALLED NEW ANGLES IAW CRJ SRM 51-40-11, 51-42-13 AND 51-42-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FS 280.00 RBL 9.0 FLOOR BEAM INBOARD AND OUTBOARD ANGLES FOUND CRACKED DURING C-CHECK INSPECTION. FIT AND INSTALLED NEW ANGLES IAW CRJ SRM 51-40-11, 51-42-13 AND 51-42-21.