What was found
FS 280.0 RBL 9.0 FLOORBEAM ANGLES INBOARD AND OUTBOARD FOUND CRACKED. FOUND DURING C CHECK INSPECTION. NEW ANGLES FIT AND INSTALLED IAW CRJ SRM 51-40-11, 51-42-06, 51-42-13 & 51-42-21. P/N: 601R31113-58
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FS 280.0 RBL 9.0 FLOORBEAM ANGLES INBOARD AND OUTBOARD FOUND CRACKED. FOUND DURING C CHECK INSPECTION. NEW ANGLES FIT AND INSTALLED IAW CRJ SRM 51-40-11, 51-42-06, 51-42-13 & 51-42-21. P/N: 601R31113-58