What was found
HYDRAULIC SYSTEM NR 1 LOW PRESSURE AMBER MESSAGE AND HYD 1A AMBER MESSAGE ON SYNOPTIC PAGE. RETURNED TO DEN. INSTALLED NR 1 HYDRAULIC SHUT OFF VALVE IAW MM 29-11-36. OPS CHECK GOOD. NO DEFECTS NOTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HYDRAULIC SYSTEM NR 1 LOW PRESSURE AMBER MESSAGE AND HYD 1A AMBER MESSAGE ON SYNOPTIC PAGE. RETURNED TO DEN. INSTALLED NR 1 HYDRAULIC SHUT OFF VALVE IAW MM 29-11-36. OPS CHECK GOOD. NO DEFECTS NOTED.