What was found
STAB CH 1 INOP, STATUS MESSAGE. WOULD NOT RE-ENGAGE DUE TO CIRCUIT BREAKER BEING POPPED. RETURNED TO SLC. REMOVED AND REPLACED STAB TRIM ACTUATOR AND MOTOR CONTROL UNIT IAW MM 27-40-00 AND 27-42-01 AND 27-42-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STAB CH 1 INOP, STATUS MESSAGE. WOULD NOT RE-ENGAGE DUE TO CIRCUIT BREAKER BEING POPPED. RETURNED TO SLC. REMOVED AND REPLACED STAB TRIM ACTUATOR AND MOTOR CONTROL UNIT IAW MM 27-40-00 AND 27-42-01 AND 27-42-05.