What was found
FLOORBEAM TO TRANSVERSE BEAM ATTACH CLIP IS CRACKED; FS 280.00; RBL 9.0; IB LOCATION. (ITEM FOUND AT C-CHECK INSPECTION.) CLIP REPLACED IAW CRJ SRM 51-40-11, 51-42-06, 51-42-21, 51-25-16 AND 51-21-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM TO TRANSVERSE BEAM ATTACH CLIP IS CRACKED; FS 280.00; RBL 9.0; IB LOCATION. (ITEM FOUND AT C-CHECK INSPECTION.) CLIP REPLACED IAW CRJ SRM 51-40-11, 51-42-06, 51-42-21, 51-25-16 AND 51-21-11.