What was found
FUSELAGE FLOORBEAM TO TRANSVERSE BEAM ATTACH CLIPS ARE CRACKED; FS 280.00, RBL 9.0 INBOARD AND OUTBOARD. ITEM FOUND AT C-CHECK INSPECTION. REPLACED CLIPS IAW CRJ SRM 51-40-11, 51-23-00, 51-42-06, 51-42-21, 51-25-16, AND 51-21-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUSELAGE FLOORBEAM TO TRANSVERSE BEAM ATTACH CLIPS ARE CRACKED; FS 280.00, RBL 9.0 INBOARD AND OUTBOARD. ITEM FOUND AT C-CHECK INSPECTION. REPLACED CLIPS IAW CRJ SRM 51-40-11, 51-23-00, 51-42-06, 51-42-21, 51-25-16, AND 51-21-11.