What was found
FUSELAGE FLOORBEAM TO TRANSVERSE BEAM ATTACH CLIP IS CRACKED; FS 280.00 LBL 9.0. ITEM FOUND AT C-CHECK INSPECTION. CLIP REPLACED IAW CRJ SRM 51-40-11, 51-42-06, 51-42-13, 51-42-21, 51-25-16 AND 51-21-11, RII 53-401.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUSELAGE FLOORBEAM TO TRANSVERSE BEAM ATTACH CLIP IS CRACKED; FS 280.00 LBL 9.0. ITEM FOUND AT C-CHECK INSPECTION. CLIP REPLACED IAW CRJ SRM 51-40-11, 51-42-06, 51-42-13, 51-42-21, 51-25-16 AND 51-21-11, RII 53-401.