What was found
AFTER LANDING WHEN FLAPS SELECTED UP, FLAP CONTROL FAULT. REMOVED AND REPLACED FLAP CONTROL UNIT IAW 27-50-06 AND CLEANED CANNON PLUGS OF GLYCOL. OPERATIONAL CHECK GOOD. P/N OFF 300500-1007, S/N OFF 0009.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFTER LANDING WHEN FLAPS SELECTED UP, FLAP CONTROL FAULT. REMOVED AND REPLACED FLAP CONTROL UNIT IAW 27-50-06 AND CLEANED CANNON PLUGS OF GLYCOL. OPERATIONAL CHECK GOOD. P/N OFF 300500-1007, S/N OFF 0009.