FUSELAGE FLOORBEAM TO TRANSVERSE BEAM ATTACH CLIP IS CRACKED; FS 280.00, LBL 9.0 OUTBOARD CLIP. ITEM FOUND AT C-CHECK INSPECTION. CLIP REPLACED IAW CRJ SRM 51-40-11, 51-42-06, 51-42-21, 51-25-16, AND 51-21-11.