Service difficulty report · Control Panel · Emb EMB120ER

Difficulty date
January 8, 2005
Submitted
January 12, 2005
Operation
Air carrier
Aircraft
N232SW
Make and model
Emb EMB120ER
Aircraft serial
120306
Aircraft time
21,188 hours, 30,891 cycles
Part
Control Panel
Condition
Malfunctioned
Location
Stall Warning
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON FFOD STALL WARNING TEST, PUSHER IS INOP ON BOTH SIDES AND POPS BOTH PUSHER CIRCUIT BREAKERS (D31 & D32). REMOVED AND REPLACED THE STALL WARNING CONTROL PANEL. SYSTEMS BOTH CHECK GOOD.