What was found
EMERGENCY FLOOR LIGHTING STRIPS BETWEEN ROWS 5-8 WILL NOT ILLUMINATE. REMOVED AND REPLACED NR 3 INVERTER FOR EMERGENCY LIGHTS IAW CRJ MM 33-51-04, OPERATIONAL CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY FLOOR LIGHTING STRIPS BETWEEN ROWS 5-8 WILL NOT ILLUMINATE. REMOVED AND REPLACED NR 3 INVERTER FOR EMERGENCY LIGHTS IAW CRJ MM 33-51-04, OPERATIONAL CHECK GOOD.