What was found
FLAP DISAGREEMENT OCCURRED WHEN SELECTING FLAPS FROM 25 DEGREES TO 45 DEGREES. LUBED LEFT AND RIGHT OUTBOARD FLAP ROLLERS, CLEANED FLAP TRACKS, ADJUSTED LEFT FLAP ACTUATOR ROD END IN IAW MM 27-50-04, OPERATIONAL CHECK GOOD IAW MM 27-50-00.