What was found
INTERCOSTAL AT FRAME 40 BETWEEN CENTER AND RT FLOORBEAMS IS CORRODED. ITEM FOUND AT C-CHECK INSPECTION. INSTALLED INTERCOSTAL IAW EMB SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INTERCOSTAL AT FRAME 40 BETWEEN CENTER AND RT FLOORBEAMS IS CORRODED. ITEM FOUND AT C-CHECK INSPECTION. INSTALLED INTERCOSTAL IAW EMB SRM 51-40-02.