What was found
"FLAP DISAGREEMENT" WHEN PLACING FLAP LEVER FROM 45 DEGREES TO 0 DEGREES. REPLACED RIGHT NACELLE FLAP ACTUATOR IAW EMB MM 27-50-08. REPLACED FLAP SELECTOR HANDLE IAW 27-50-01. OPERATIONAL CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
"FLAP DISAGREEMENT" WHEN PLACING FLAP LEVER FROM 45 DEGREES TO 0 DEGREES. REPLACED RIGHT NACELLE FLAP ACTUATOR IAW EMB MM 27-50-08. REPLACED FLAP SELECTOR HANDLE IAW 27-50-01. OPERATIONAL CHECK GOOD.