What was found
FRAME FLANGE CRACKED AT FS 605 STR 9L ABOVE STRINGER FROM LOWER FASTENER HOLE TO EDGE OF FLANGE. ITEM FOUND AT C-CHECK INSPECTION. REPAIRED FLANGE IAW CRJ REO 601R-53-61-1507.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME FLANGE CRACKED AT FS 605 STR 9L ABOVE STRINGER FROM LOWER FASTENER HOLE TO EDGE OF FLANGE. ITEM FOUND AT C-CHECK INSPECTION. REPAIRED FLANGE IAW CRJ REO 601R-53-61-1507.