What was found
FORWARD SECTION EMERGENCY LIGHTING INOP. WIRES BROKEN AT FORWARD FLOOR CONNECTION. REPAIRED BROKEN WIRE AND REPLACED 1 EMERGENCY LIGHT IAW 33-00-00. OPERATIONAL CHECKS GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD SECTION EMERGENCY LIGHTING INOP. WIRES BROKEN AT FORWARD FLOOR CONNECTION. REPAIRED BROKEN WIRE AND REPLACED 1 EMERGENCY LIGHT IAW 33-00-00. OPERATIONAL CHECKS GOOD.