What was found
FLIGHT ATTENDANT REPORTED OVERHEATED ODOR COMING OUT OF HOT JUGS. SWITCH WAS TURNED OFF AND ODOR DISAPPEARED. REPLACED HOT JUG WITH SERVICEABLE UNIT IAW 25-60-00. OPERATIONAL CHECKS GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLIGHT ATTENDANT REPORTED OVERHEATED ODOR COMING OUT OF HOT JUGS. SWITCH WAS TURNED OFF AND ODOR DISAPPEARED. REPLACED HOT JUG WITH SERVICEABLE UNIT IAW 25-60-00. OPERATIONAL CHECKS GOOD.