FLOOR SUPPORT STRUCTURE AT FS 484 RBL 30 HAS A CRACKED ANGLE, DISCOVERED AT C-CHECK. REPLACED CLIP PN 601R31171-9 PER REO 601R-53-41-059.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT STRUCTURE AT FS 484 RBL 30 HAS A CRACKED ANGLE, DISCOVERED AT C-CHECK. REPLACED CLIP PN 601R31171-9 PER REO 601R-53-41-059.