What was found
RIVET SHEARED ON FLOOR SUPPORT BEAM BRACKET AT FS 461 AND LBL9, FOUND AT C-CHECK. COMPLIED WITH NECESSARY REPAIRS PER CRJ200 SRM 51-42-06 PG 11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIVET SHEARED ON FLOOR SUPPORT BEAM BRACKET AT FS 461 AND LBL9, FOUND AT C-CHECK. COMPLIED WITH NECESSARY REPAIRS PER CRJ200 SRM 51-42-06 PG 11.