As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EMERGENCY FLOOR LIGHT STRIPS NR 2, 3, 4 AND 5 INOPERATIVE AND FLOOR LEVEL EMERGENCY EXIT ROW EXIT LIGHT INOP WHEN EMERGENCY LIGHT SWITCH ON. (FLT 6493) REPLACED NR 2 INVERTER, NR 2 BATTERY CHARGER AND BATTERY PACK IAW AMM PN AD-2013-1A S/N ON 72485 S/N OFF 50480.