What was found
HYDRAULIC 2, LOW PRESS CAUTION. QTY INDICATED 5 PERCENT, HYD PUMP 2B CAUTION AND EDP 2A CAUTION FOLLOWED. REPLACED O-RINGS ON NR 2 ACMP LINE, LEAK CHECKED OK IAW AMM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HYDRAULIC 2, LOW PRESS CAUTION. QTY INDICATED 5 PERCENT, HYD PUMP 2B CAUTION AND EDP 2A CAUTION FOLLOWED. REPLACED O-RINGS ON NR 2 ACMP LINE, LEAK CHECKED OK IAW AMM.