What was found
LOWER INTERCOSTAL AT STRINGER 20 RT BETWEEN FS 310 & FS 349 HAS LEVEL 2 CORROSION ON IT NUMEROUS AREAS, BELOW SERVICE DOOR CUTOUT. C-CHECK REPLACED TWO EACH INTERCOSTAL AT STRINGER 20 RT BETWEEN FS 310 TO 320 & FS 320 TO 349 IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LOWER INTERCOSTAL AT STRINGER 20 RT BETWEEN FS 310 & FS 349 HAS LEVEL 2 CORROSION ON IT NUMEROUS AREAS, BELOW SERVICE DOOR CUTOUT. C-CHECK REPLACED TWO EACH INTERCOSTAL AT STRINGER 20 RT BETWEEN FS 310 TO 320 & FS 320 TO 349 IAW SRM.