BS 349 TOP OF FLOORBEAM AT END WHERE IT MEETS LWR SILL AND FITTING THAT TIES SILLS TOGETHER HAS CORROSION ON TOP AND BETWEEN AFT SIDE OF BEAM AND SILL. C-CHECK, BLENDED AND TREATED IAW SRM AND EA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 349 TOP OF FLOORBEAM AT END WHERE IT MEETS LWR SILL AND FITTING THAT TIES SILLS TOGETHER HAS CORROSION ON TOP AND BETWEEN AFT SIDE OF BEAM AND SILL. C-CHECK, BLENDED AND TREATED IAW SRM AND EA.