What was found
LATCH ON LAVATORY BROKEN WITH PASSENGER STUCK INSIDE. PASSENGER INDICATED HE MIGHT HAVE A MEDICAL CONDITION THAT WARRANTED USING THE CRASH AXE TO PRY THE DOOR OPEN. DAMAGE WAS DONE TO DOOR FRAME AND LAVATORY DOOR. FOUND LAVATORY DOOR LATCH TO BE DAMAGED INTERNALLY. R & R LATCH IAW CMM. FOUND UPPER DOOR TRACK BADLY BENT OUT OF SHAPE. R & R LAV DOOR UPPER DOOR TRACK IAW CMM. BLENDED SHARP EDGES FROM DOOR FRAME. LAV DOOR NOW FUNCTIONS PROPERLY. OPS CHECK GOOD.