What was found
WHILE PERFORMING EDDY CURRENT NDT INSPECTION OF THE BS 621 AFT PRESSURE BULKHEAD, FOUND CRACK INDICATION AT THE FOLLOWING LOCATION: .5" LEFT, FWD-LOOKING-AFT, OF RBL 9.50, 24-.6250" UP FROM WL 73.50 AND 22.5" DOWN FROM WL 120.43. INDICATION RUNS VERTICAL APPROXIMATELY .5" IN LENGTH. C-CHECK, REPAIRED BULKHEAD IAW REO.