Service difficulty report · A/C Pack · Emb EMB120ER

Difficulty date
August 30, 2014
Submitted
September 12, 2014
Operation
Air carrier
Aircraft
N563SW
Make and model
Emb EMB120ER
Aircraft serial
120338
Aircraft time
34,515 hours, 48,464 cycles
Part
A/C Pack
Condition
Smoke
Location
Right
Stage of operation
NR
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SMOKE ALARM GOES OFF WHEN THE RIGHT PACK IS RUNNING IN AUTO OR NORM. MESSAGE CLEARED WHEN RIGHT PACK IS TURNED OFF. RIGHT COOLING GROUND FAN OPERATES AS NORMAL ON GROUND. PERFORMED AN OPS CHECK OF THE RIGHT PACK IAW AMM. OPERATED THE RT PACK ON GROUND FOR 30 MINUTES AND THE SMOKE ALARM WOULD NOT TRIP. OPS CHECKED GOOD.