What was found
AVIONICS COMPARTMENT DOOR SURROUND STRUCTURE, INTERCOSTAL 27 RT HAS CORROSION AT STA FS 364. C-CHECK, RO 2/20/15, WORK DONE IN REF TO EA, STS EA. CORROSION REMOVED AT DISCREPANT LOCATIONS ALONG THE ATTATCHMENT FLANGE ON RT INTERCOSTAL. NOMINAL THICK=0.080", REMAINING THICK=0.078" MATERIAL REMOVED=0.002" ALONG THE ENTIRE FLANGE. AREA REPAIRED REF STS EA.