Service difficulty report · Floor Support · Cndair CL6002B19

Difficulty date
February 3, 2015
Submitted
February 21, 2015
Operation
Air carrier
Aircraft
N449SW
Make and model
Cndair CL6002B19
Aircraft serial
7699
Aircraft time
29,251 hours, 24,272 cycles
Part
Floor Support
Condition
Corroded
Location
Bs 484
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PASSENGER CABIN LT FLOOR SILL ANGLE FS484 AT LBL45 HAS CORROSION. C-CHECK, RO 2/19/15, FLOOR SILL REPAIRED AT DISCREPANT AREAS REF REO 1, BLEND IS ON THE FLOOR SILL PANEL, PN 601R31145-139 ON THE PAD UP AREA AT FS 486 AT LBL 45, NOMINAL THICKNESS=0.080"?, REMAINING THICKNESS=0.059"?. THEREFORE MATERIAL REMOVED WAS 0.021"?. THE OTHER BLEND WAS ON THE FLOOR SILL ANGLE, PN 601R31145-219 AT FS 484 AT LBL 45, NOMINAL THICKNESS=0.080, REMAINING THICKNESS=0.076"?. THEREFORE THE MATERIAL REMOVED WAS 0.004"?. BOTH BLENDS ARE WITHIN LIMITS REF REO.