What was found
UPON MOVING 232BRF FLOORBOARD DISCOVERED CORROSION ON FLOOR SUPPORT JUST FWD OF RT SIDE SERVICE DOOR. REMOVED AND INSTALLED NEW SERVICABLE RT FLOOR SUPPPORT FROM BS 280.00-319.70 IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
UPON MOVING 232BRF FLOORBOARD DISCOVERED CORROSION ON FLOOR SUPPORT JUST FWD OF RT SIDE SERVICE DOOR. REMOVED AND INSTALLED NEW SERVICABLE RT FLOOR SUPPPORT FROM BS 280.00-319.70 IAW SRM.