What was found
FLOORBEAM ATTACH FITTING AT BS 621, LBL 27 IS CORRODED ON THE INBD SIDE AND GOUGED ON TOP SIDE. REMOVED AND REPLACED THE ATTACH FITTING IAW REO.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM ATTACH FITTING AT BS 621, LBL 27 IS CORRODED ON THE INBD SIDE AND GOUGED ON TOP SIDE. REMOVED AND REPLACED THE ATTACH FITTING IAW REO.