What was found
GEAR DISAGREE MESSAGE. (FLT 4118) FO: 7/12/2018 CLOSED ADJUSTED NLG PROX SENSORS PS13GA & PS4GA IAW AMM. OPS CHECK GOOD. REMOVED AND REPLACED NLG ALTERNATE GEAR AND DOOR BYPASS VALVES FOR T/S. OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GEAR DISAGREE MESSAGE. (FLT 4118) FO: 7/12/2018 CLOSED ADJUSTED NLG PROX SENSORS PS13GA & PS4GA IAW AMM. OPS CHECK GOOD. REMOVED AND REPLACED NLG ALTERNATE GEAR AND DOOR BYPASS VALVES FOR T/S. OPS CHECK GOOD.