What was found
CORROSION FOUND ON STR 26R, FS333 TO FS364. (C-CHECK) RO: 11/1/2018. REPLACED STRINGER AT STR26, FS333 - FS364 REF SRM 51-42-06-001-001-A01. LEAK CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON STR 26R, FS333 TO FS364. (C-CHECK) RO: 11/1/2018. REPLACED STRINGER AT STR26, FS333 - FS364 REF SRM 51-42-06-001-001-A01. LEAK CHECK GOOD.