Service difficulty report · Floor Support · Cndair CL6002B19
FAA SDR system
- Difficulty date
- July 11, 2019
- Submitted
- August 23, 2019
- Operation
- Air carrier
- Make and model
- Cndair CL6002B19
- Aircraft serial
- 7657
- Aircraft time
- 43,081 hours, 36,816 cycles
- Part
- Floor Support
- Condition
- Corroded
- Location
- Bs 409-559
- Stage of operation
- IN
- How discovered
- 9
- Nature of condition
- O
- Precautionary procedure
- K
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
L/H PRESSURE FLOOR ANGLE BETWEEN APPROX FS 409.00 + 128 THRU APPROX FS 559.00 HAS AREAS OF CORROSION. (C-CHECK) RO: 08/22/2019 BLENDED OUT CORROSION ON L/H PRESSURE FLOOR ANGLE BETWEEN APPROX FS 409.00 + 128 THRU APPROX FS 559.00 IAW REO. LEAK CHECK GOOD.