What was found
R/H FLOOR SILL HAS SPOTS OF CORROSION FROM APPROX. 409+100 TO 409+128. (C-CHECK) RO: 08/22/2019 REPAIRED RH FLOOR SILL IAW SRM AND REO.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R/H FLOOR SILL HAS SPOTS OF CORROSION FROM APPROX. 409+100 TO 409+128. (C-CHECK) RO: 08/22/2019 REPAIRED RH FLOOR SILL IAW SRM AND REO.