What was found
FLAP HINGE FAIRING 592BB GUIDE PLATE CHAFED. (C-CHECK) RO: 11/3/2019 ORIGINAL GUIDE PLATE THICKNESS .045, CHAFE DAMAGE .017, REMAINING THICKNESS .028 FOUND TO BE OUT OF LIMITS IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLAP HINGE FAIRING 592BB GUIDE PLATE CHAFED. (C-CHECK) RO: 11/3/2019 ORIGINAL GUIDE PLATE THICKNESS .045, CHAFE DAMAGE .017, REMAINING THICKNESS .028 FOUND TO BE OUT OF LIMITS IAW SRM.