What was found
#3 HYD FAIL MSSG ON ARR 5000FT WITH FLAPS AND GEAR UP. HYD LOW PRESSURE CAUTION ALONG WITH IB GROUND SPOILER CAUTION MSSG. CHECKED HYD SYS SYNOPTIC - FOUND HYD 3 QTY AND PRESSURE AT 0 FLIGHT 3798 CLOSEDTHIS DISCREPANCY WAS TRANSFERRED TO CAMP ITEM 19898638 WITH THE FOLLOWING CORRECTIVE ACTION: "SEE CP 19900802 AND CP 19900797 FOR HYD ACMP 3A FOR REMOVAL AND REPLACEMENT.SEE CP 19900806 AND CP 19900800 FOR REMOVAL AND REPLACEMENT OF HYD ACMP 3B AND REF: CP 19903072 FOR LEAKING IMPENDING BYPASS. #3 HYDRAULIC SYSTEM OPS CHECK GOOD AT THIS TIME AND NO LEAKS NOTED."