What was found
FLOORBEAM CORRODED AT FS559+112, LBL38.5 AROUND NUTPLATE HOLE. (C-CHECK) RO 12/14/2019 REMOVED CORROSION FROM FLOOR BEAM LBL 36 AT FS 559+112 FROM DISCREPANT AREA IAW CRJ 200 SRM AND FOUND TO BE WITHIN LIMITS IAW CRJ 200 SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM CORRODED AT FS559+112, LBL38.5 AROUND NUTPLATE HOLE. (C-CHECK) RO 12/14/2019 REMOVED CORROSION FROM FLOOR BEAM LBL 36 AT FS 559+112 FROM DISCREPANT AREA IAW CRJ 200 SRM AND FOUND TO BE WITHIN LIMITS IAW CRJ 200 SRM.