What was found
BS 310 BELOW FLOOR SUPPORT, STRINGER 20R INTERCOSTAL HAS CORROSION ON FWD PORTION. REMOVED AND REPLACED THE INTERCOSTAL IAW DWG SH670-31950, REV Y, AND SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 310 BELOW FLOOR SUPPORT, STRINGER 20R INTERCOSTAL HAS CORROSION ON FWD PORTION. REMOVED AND REPLACED THE INTERCOSTAL IAW DWG SH670-31950, REV Y, AND SRM.