What was found
LBL 9 FLOOR SUPPORT CAP INBOARD FLANGE HAD CORROSION AT MULTIPLE LOCATIONS BETWEEN BS 409+6 AND 409+118. INSTALLED A NEW FABRICATED FLOOR SUPPORT CAP IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LBL 9 FLOOR SUPPORT CAP INBOARD FLANGE HAD CORROSION AT MULTIPLE LOCATIONS BETWEEN BS 409+6 AND 409+118. INSTALLED A NEW FABRICATED FLOOR SUPPORT CAP IAW SRM.