FLOOR SUPPORT BETWEEN BS 559+64 - 559+80, RBL 9, WAS CORRODED. EXFOLIATED BEYOND REPAIR. 100% MATERIAL LOSS. OUT OF LIMITS. FABRICATED AND INSTALLED A NEW REPLACEMENT FLOOR SUPPORT. INSTALLED IAW DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.