What was found
3EA AREAS OF CRACK INDICATIONS NOTED ON FS621 RPB WEB, 2EA IN THE HEEL LINE AREA OF VERT POSTS, 1ST AT BL0 WL108.5-WL111.5 50%FSH, 2ND AT LBL36 WL78.75-WL79.25 50%FSH, AND 3RD AT LOWER I/B CORNER OF LINTEL FITTING 0.350€? 100%FSH. MARKED ON A/C. ALL 3EA AREAS OF INDICATIONS NOTED FAILED NDT (C-CHECK) RO 12/27/2019 COMPLIED WITH 3EA AREAS OF CRACK INDICATIONS NOTED ON FS621 RPB WEB, 2EA IN THE HEEL LINE AREA OF VERT POSTS, 1ST AT BL0 WL108.5-WL111.5 50%FSH, 2ND AT LBL36 WL78.75-WL79.25 50%FSH, AND 3RD AT LOWER I/B CORNER OF LINTEL FITTING 0.350€? 100%FSH IAW REO.