What was found
FS 513.0 INTERCOSTAL BETWEEN RH PRESSURE SILL AND RBL 27 HAS CRACKED CLIP ON OTBD END (C-CHECK) RO 1/28/2020 REMOVED AND REPLACED ANGLE AT FS513 BETWEEN RH PRESSURE SILL AND RBL 27 REF CRJ 200 SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FS 513.0 INTERCOSTAL BETWEEN RH PRESSURE SILL AND RBL 27 HAS CRACKED CLIP ON OTBD END (C-CHECK) RO 1/28/2020 REMOVED AND REPLACED ANGLE AT FS513 BETWEEN RH PRESSURE SILL AND RBL 27 REF CRJ 200 SRM.