What was found
*PAX DOOR LOWER SILL ANGLE CORRODE IN SEVERAL PLACES FWD NUTPLATE HOLES (MARKED) (C-CHECK) RO:1/29/2020FOUND CORROSION IS LOCATED ON PASSENGER DOOR FOWARD RAIL CUPS AT NUTPLATE HOLES AND NOT PAX DOOR LOWER SILL ANGLE . REMOVED CORROSION ON PASSENGER DOOR SURROUND FORWARD HAND RAIL CUPS. REF CRJ-200 SRM. BLENDED AREA WAS FOUND TO BE OUT OF LIMITS REF CRJ-200-SRM. REMOVED AND REPLACED WITH NEW RAIL CUP/BRACKET ASSY 601R31527-217 CRJ-200-SRM AND BOMBARDIER DWG.