What was found
FS280.00 BEAM AREAS OF CORROSION, (COCKPIT ENTRYWAY) MARKED (C-CHECK) RO:1/29/2020REMOVED CORROSION FROM FS280.00 BEAM AREA (COCKPIT ENTRYWAY) REF CRJ 200 SRM. ORIGINAL MATERIAL THICKNESS IS .040, REF CRJ200 SRM. THE REMAINING THICKNESS IS .034 MATERIAL LOSS IS .006 THE MAX LOSS ALLOWED IS .004. FOUND TO BE OUT OF LIMITS. REF CRJ200 SRM. RECEIVED REO BOMBARDIER REO THE AREA IS STRUCTURALLY ACCEPTABLE ALL STEPS COMPLIED WITH. RESTORED FINISH AND CIC AS REQUIRED. COMPLIED WITH SKYWEST TASK CARD.