What was found
DURING INSPECTION OF LH WING LOWER PLANK ACCESS HOLE PITTING WAS FOUND (550FB) (C CHECK) RO 3/2/2020 ACCOMPLISH REPAIR OF LH WING LOWER PLANK ACCESS PANEL LANDING 550FB BLEND WAS FOUND OUTSIDE OF CRITICAL AREA. ORIGINAL .182, REMOVED .003, REMAINING .179 NO FURTHER INSPECTION REQUIRED.BOND CHECK GOOD, LEAK CHECK GOOD. REGULATOR AG1157 OCT 20, TACH AV 1335 JUL 20 EDDY CURRENT AV8958 JUL 20, ULTRASONIC AV8959 JUL 20 PIN POINT MIC AV8098 DEC 20 MILLIOHMETER AV6346 AUG 20 TORQUE WRENCH AV7330 NOV 20